Call Us
E-mail :lincoambala@gmail.com
Automatic Polarimeter

Automatic Polarimeter

71500 INR/Piece

Product Details:

  • Frequency 50 Hz
  • Voltage 220V
  • Power Source AC Electric
  • Accuracy ±0.01°
  • Core Components LED Light Source, Photoelectric Detection, Control System
  • Model No APM-1000
  • Capacity 0-8 Optical Rotation Angle (°) / 0.01ml Sample Volume
  • Click to View more
X

Automatic Polarimeter Price And Quantity

  • 1 Piece
  • 71500 INR/Piece

Automatic Polarimeter Product Specifications

  • 5°C – 35°C
  • Approx. 12 kg
  • -45° to +45° Optical Rotation
  • Auto Calibration, High Precision, Easy Operation
  • Automatic
  • 600 x 320 x 220 mm
  • APM-1000
  • Laboratory / Quality Control
  • LCD Digital Display
  • 0-8 Optical Rotation Angle (°) / 0.01ml Sample Volume
  • ±0.01°
  • LED Light Source, Photoelectric Detection, Control System
  • Stainless Steel and Optical Glass
  • 50 Hz
  • 220V
  • Automatic Polarimeter
  • AC Electric

Automatic Polarimeter Trade Information

  • Cash in Advance (CID)
  • All India

Product Description

Automatic Polarimeter:


1. Three Stages of Quality Checking before Dispatch.

2. Automatic Repetition - Measurement for 6 times, and Calculation of Average Value.

3. Choice of 3 Pin Power Cord / Dust Cover Supplied.

4. Online Installation/ Demonstration Provide Free of Cost.

5. Demonstration / Installation Video CD are Provide at Free of Cost.



Exceptional Measurement Accuracy and Range

The APM-1000 offers remarkable precision with a measurement range from -45 to +45 and a resolution of 0.001. Thanks to its advanced photoelectric detection system and stable LED light source, laboratories can trust its consistent and accurate results. The instrument is ideal for demanding applications in pharmaceuticals, food, and chemical analysis, ensuring reliable quality control.


User-Friendly Operation and Smart Features

Engineered for ease of use, the polarimeter boasts an intuitive LCD digital display with both English and Chinese language support. Automated calibration, simple sample tube insertion, and clear data output make everyday operation straightforward. The auto-calibration feature minimizes human error, and all readings are stored for convenience, supporting up to 200 data sets.


Sturdy Design Suited for Modern Laboratories

Constructed from high-grade stainless steel and optical glass, the APM-1000 is built to withstand rigorous laboratory use. It operates efficiently in ambient temperatures from 5C to 35C and humidity levels up to 85% RH. With protective features against overload and over-temperature, this model is both safe and durable for long-term laboratory or quality assurance tasks.

FAQ's of Automatic Polarimeter:


Q: How does the APM-1000 Automatic Polarimeter ensure precise measurements?

A: The APM-1000 uses a stable LED at 589 nm (sodium D-line), a high-resolution photoelectric detection system, and auto-calibration, allowing it to achieve accuracy up to 0.01 with a resolution of 0.001. This minimizes manual errors and offers consistent, high-precision readings suitable for sensitive analyses.

Q: What is the typical process for using the APM-1000 in a laboratory setting?

A: To operate the APM-1000, users first insert the sample tube (100 mm or 200 mm), select the appropriate language on the LCD display, and initiate the measurement. The device automatically calibrates, measures the sample's optical rotation, then stores the result. Data can be exported via the RS232 interface for further analysis.

Q: When should the auto-calibration feature be used?

A: Auto-calibration should be performed before initiating a new batch of measurements, after relocating the device, or whenever the polarimeter's accuracy is in question. This feature ensures the instrument remains optimally configured for reliable results.

Q: Where can data measured by the APM-1000 be stored and accessed?

A: The APM-1000 stores up to 200 sets of measurement data internally, which can be accessed directly on the LCD digital display. For archiving or analysis, data can be exported using the RS232 interface to a computer or compatible data system.

Q: What are the main benefits of using this automatic polarimeter?

A: Key advantages include fast and precise measurement, auto calibration to reduce human error, easy operation thanks to its digital display and language support, robust construction, and reliable data storage. These features collectively streamline workflow and enhance data accuracy in laboratory or quality control settings.

Q: How does overload and over-temperature protection work in this device?

A: The APM-1000 is equipped with protective mechanisms that automatically halt operation during unsafe conditions such as overheating or electrical overload, safeguarding both the instrument and samples from damage.

Q: What types of environments and samples is the APM-1000 suitable for?

A: Designed for normal laboratory conditions (temperature range of 5C to 35C and humidity up to 85% RH), the APM-1000 is suitable for analyzing solutions in pharmaceutical, chemical, and food laboratories, making it ideal for quality control and research applications.

Tell us about your requirement
product

Price:  

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Digital Polarimeter' category



Back to top
trade india member
LABORATORY INSTRUMENTS AND CHEMICALS All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.